Product Introduction
REG1K0200G is specifically designed for high-power DC chargers to enable electric vehicle fast charging and supports Variable Power Factor (VPF) function. It features high efficiency, low fan noise, high power density, and high reliability. With 3-phase 4-wire AC input, it can deliver up to 62.5kW DC output power and support an output voltage range of 200Vdc~1000Vdc. It meets EMC/EMI Class B requirements, and has TUV CE, cTUVus, and KC certification.
-
Integrated input AC contactor, achieving standby state with zero reactive power
-
Variable Power Factor (VPF) function, PF adjustable 0.8 leading ~ 0.8 lagging
-
Peak efficiency ≥97.5%, full load efficiency ≥97%
-
Conformal coating and glue filling provide enhanced protection for high reliability
-
Full power 62.5kW output, max reactive power compensation 62.5kVar
-
EMC/EMI Class B standard
Curve Chart
-
Output Power and Input Voltage Curve
-
Output Voltage and Output Current Curve
-
Output Power and Ambient Temperature Curve
Technical Specification
-
REG1K0200G
-
Operating Environment
Operating temperature -40°C~+75°C, power derating from 55°C Transportation/Storage -40°C~+75°C Relative humidity ≤95%RH, non-condensing Altitude 4000m Atmospheric pressure 79kPa~106kPa Cooling method Forced air cooling Protection rating IP20 Noise Standard mode: ≤65dB; de-noise mode: ≤60dB; silent mode: ≤55dB -
AC Input
Frequency 45Hz~65Hz Input voltage 3-phase+PE, 260Vac~530Vac Rated voltage 380/400/480Vac Max input current 120A Power factor ≥0.99 PF adjustment range 0.8 leading ~ 0.8 lagging Reactive power compensation -62.5kVar~+62.5kVar Standby power <8.2W Input AC contactor Integrated input AC contactor, achieving standby state with zero reactive power THDi ≤5% -
DC Output
Max output power 62.5kW Output voltage 200Vdc~1000Vdc Constant power voltage range 312.5Vdc~1000Vdc Output current 0~200A Voltage regulation accuracy <±0.5% Current regulation accuracy ≤±1% Current sharing <±1% Peak efficiency ≥97.5% Full load efficiency ≥97% -
Control
Communication CAN bus, max 40 power modules in parallel Indicator light Green LED: normal operation; Yellow LED: alarm; Red LED: failure Address indication Automatic address identification, panel dial switch for group setting ESTOP 5V/12V dry-contact relay trigger, output voltage shall drop from -
Alarm and Protection
Input overvoltage/undervoltage protection Automatic shutdown, enters standby mode when the voltage returns to normal and requires a startup command from the monitoring unit to restore output Output overvoltage protection Automatic shutdown, manual restart when the voltage returns to normal Overcurrent/short circuit protection Automatic shutdown, enters standby mode when the overcurrent/short circuit is cleared and requires a startup command from the monitoring unit to restore output Overtemperature protection Automatic shutdown, enters standby mode when the temperature returns to normal and requires a startup command from the monitoring unit to restore output -
Reliability and Safety
Certification TUV CE, cTUVus, KC EMC/EMI EN IEC 61851-21-2:2021 Class B Safety IEC 61851-1:2023, IEC 61851 23:2023, EN IEC 61851-1:2019, EN MTBF >300,000h -
Mechanical Parameters
Dimensions (W*D*H) 385mm*403mm*110mm Weight 28kg