INFY INFY
REG1K5125G2

50kW 1500V
MCS VPF ACDC Power Module

新建项目 (1).svg
INFY

Product Introduction

REG1K5125G2 is a Megawatt Charging System (MCS) charging module specifically designed for electric vehicle fast charging applications requiring power factor adjustment or reactive power compensation, and supports Variable Power Factor (VPF) function. It features 3-phase AC input without a neutral line, offering a wide PF adjustment range, extensive reactive power compensation, high efficiency, high power density, and low harmonic distortion. It has TUV CE and cTUVus certification.



Product Values

Technical Specification

  • REG1K5125G2
  • Operating Environment
    INFY
      Operating temperature-40°C~+75°C, derating is required above 55°C
      Transportation/Storage temperature-40°C~+70°C
      Relative humidity≤95%RH, non-condensing
      Altitude2000m
      Atmospheric pressure79kPa~106kPa
      Cooling methodForced air cooling
      NoiseStandard mode: ≤80dB; de-noise mode: ≤65dB; silent mode: ≤55dB
  • AC Input
    INFY
      Frequency45Hz~65Hz
      Input voltage3-phase+PE, 260Vac~530Vac
      Rated voltage380Vac/480Vac
      Max input current95A
      Power factor≥0.99
      PF adjustment range0.8 leading ~ 0.8 lagging
      Operating modeFour operating modes: standard, constant PF control, pure reactive compensation, active and reactive power hybrid output
      Reactive power compensation-50kVar~+50kVar
      Standby power<10W            
      THDi≤5%
  • DC Output
    INFY
    • Max output power

      50kW

    • voltage  

      150Vdc~1500Vdc  

    • Constant power voltage range

      400Vdc~1500Vdc

    • Current  

      0~125A  

    • Voltage regulation accuracy

      <±0.5%

    • Current regulation accuracy

      ≤±1%

    • Current sharing  

      ≤±3%  

    • Peak efficiency

      ≥97.7%

    • Full load efficiency  

      ≥97%@1500V

  • Control
    INFY
    • Communication

      CAN bus, max 40 power modules in parallel

    • Indicator light

      Green LED: normal operation; Yellow LED: alarm; Red LED: failure

    • Address indication

      Automatic address identification, panel dial switch for group setting

    • ESTOP

      5V~15V dry-contact relay trigger, output voltage shall drop from 1500Vdc to below 60Vdc in 300ms

  • Alarm and Protection
    INFY
    • Input overvoltage/undervoltage protection

      Automatic shutdown, enters standby mode when the voltage returns to normal and requires a startup command from the monitoring unit to restore output

    • Output overvoltage protection

      Automatic shutdown, manual restart when the voltage returns to normal

    • Overcurrent/short circuit protection

      Automatic shutdown, enters standby mode when the overcurrent/short circuit is cleared and requires a startup command from the monitoring unit to restore output

    • Input Overtemperature protection

      Automatic shutdown, enters standby mode when the temperature returns to normal and requires a startup command from the monitoring unit to restore output

  • Reliability and Safety
    INFY
    • Certification

      TUV CE, cTUVus

    • EMC/EMI

      EN IEC 61851-21-2:2021 Class B

    • Safety

      IEC 61851-1:2023, EN IEC 61851-1:2019, EN 61851-23:2014, IEC 61851-23:2023, UL 2202:2022

    • MTBF

      >300,000h

  • Mechanical Parameters
    INFY
    • Mechanical Parameters-Dimensions (W*D*H)

      300mm*416mm*84mm

    • Mechanical Parameters-Weight

      ≤20kg