Product Introduction
REG1K5125G2 is a Megawatt Charging System (MCS) charging module specifically designed for electric vehicle fast charging applications requiring power factor adjustment or reactive power compensation, and supports Variable Power Factor (VPF) function. It features 3-phase AC input without a neutral line, offering a wide PF adjustment range, extensive reactive power compensation, high efficiency, high power density, and low harmonic distortion. It has TUV CE and cTUVus certification.
-
Supports 1500V MCS charging voltage requirements
-
Full power 50kW output, PF adjustable 0.8 leading ~ 0.8 lagging, max reactive power compensation 50kVar
-
Shelf-level installation compatible with G2 platform modules
-
Peak efficiency ≥97.7%, full load efficiency ≥97%
-
Conformal coating and glue filling provide enhanced protection for high reliability
-
Wide output voltage range: 150Vdc~1500Vdc
Product Values
-
Output Power and Power Factor Curve
-
Output Power and Ambient Temperature Curve
-
Output Power and Input Voltage Curve
-
Output Voltage and Output Current Curve
Technical Specification
-
REG1K5125G2
-
Operating Environment
Operating temperature -40°C~+75°C, derating is required above 55°C Transportation/Storage temperature -40°C~+70°C Relative humidity ≤95%RH, non-condensing Altitude 2000m Atmospheric pressure 79kPa~106kPa Cooling method Forced air cooling Noise Standard mode: ≤80dB; de-noise mode: ≤65dB; silent mode: ≤55dB -
AC Input
Frequency 45Hz~65Hz Input voltage 3-phase+PE, 260Vac~530Vac Rated voltage 380Vac/480Vac Max input current 95A Power factor ≥0.99 PF adjustment range 0.8 leading ~ 0.8 lagging Operating mode Four operating modes: standard, constant PF control, pure reactive compensation, active and reactive power hybrid output Reactive power compensation -50kVar~+50kVar Standby power <10W THDi ≤5% -
DC Output
Max output power
50kW
voltage
150Vdc~1500Vdc
Constant power voltage range
400Vdc~1500Vdc
Current
0~125A
Voltage regulation accuracy
<±0.5%
Current regulation accuracy
≤±1%
Current sharing
≤±3%
Peak efficiency
≥97.7%
Full load efficiency
≥97%@1500V
-
Control
Communication
CAN bus, max 40 power modules in parallel
Indicator light
Green LED: normal operation; Yellow LED: alarm; Red LED: failure
Address indication
Automatic address identification, panel dial switch for group setting
ESTOP
5V~15V dry-contact relay trigger, output voltage shall drop from 1500Vdc to below 60Vdc in 300ms
-
Alarm and Protection
Input overvoltage/undervoltage protection
Automatic shutdown, enters standby mode when the voltage returns to normal and requires a startup command from the monitoring unit to restore output
Output overvoltage protection
Automatic shutdown, manual restart when the voltage returns to normal
Overcurrent/short circuit protection
Automatic shutdown, enters standby mode when the overcurrent/short circuit is cleared and requires a startup command from the monitoring unit to restore output
Input Overtemperature protection
Automatic shutdown, enters standby mode when the temperature returns to normal and requires a startup command from the monitoring unit to restore output
-
Reliability and Safety
Certification
TUV CE, cTUVus
EMC/EMI
EN IEC 61851-21-2:2021 Class B
Safety
IEC 61851-1:2023, EN IEC 61851-1:2019, EN 61851-23:2014, IEC 61851-23:2023, UL 2202:2022
MTBF
>300,000h
-
Mechanical Parameters
Mechanical Parameters-Dimensions (W*D*H)
300mm*416mm*84mm
Mechanical Parameters-Weight
≤20kg