INFY INFY
EXP07K1E-FSW

7kW 750V Single Phase V2G/V2H DC Wallbox Charger

7kW V2H.png
INFY

Product Introduction

EXP07K1E is the bidirectional 7kW DC wall box for V2G/V2H and B2G/B2H applications, to connect the EV battery or the
Residential energy storage battery to the single phase AC grid to realize the EV dis/charging V2G function and Home power
backup V2H function. These V2G/V2H and B2G/B2H functions enable EV battery and residential battery to be used for grid energy
storage, backup power supply and smart grid node.

Application

  • EXP07K1E_FSW
    INFY
    EXP07K1E_FSW_01(1).svg
  • EXP07K1E_FSW
    INFY
    EXP07K1E_FSW_02.svg

V2H Solution

Technical Specification

  • EXP07K1E-FSW
  • Environmental
    INFY
      Ambient temperature-40°C~75°C, derating from 45°C
      CoolingFan cooling
      Altitude2000m
  • Charging mode-AC input
    INFY
      Input voltage & current230Vac, L+N+PE; 32A
      Input voltage/frequency range100 Vac~264 Vac, 45 Hz~65 Hz
      Power factor≥0.98 full-load output power of @50%~100%
      THD≤5% full-load output power of @50%~100%
  • Charging mode-DC output
    INFY
      Rated power6.2kW
      Voltage and current range300Vdc~750Vdc, 0~20.7A
      Efficiency (max)≥95.0%
  • Charging mode-V2G AC box
    INFY
      If there is no V2H box, need to select this boxAC energy meter, SPD, AC distribution
  • Charging and V2G mode convertion time (battery test)
    INFY
      100ms
  • V2G mode-DC input
    INFY
      DC input voltage and output power300~750V/6.2kW
      Max input current22A
  • V2G mode-AC output
    INFY
      Output AC voltage and output power230V/6.2kW
      Rated power and current6.2kW/27A
      Output AC frequency50Hz/60Hz
      THDi/output power factor<5%/user setting, 0.8 leading~0.8 lagging
      Efficiency (max)≥95.0%
  • V2G mode-Off grid
    INFY
      Voltage accuracy and distortion 1% and <3%/off grid only support 230Vac
      Power factor 0.8~1
      Dynamic volt stability & recovery time 5% and 20ms
  • V2G mode-V2H (optional)
    INFY
      V2H boxBidirectional mid AC energy meter, SPD, AC distribution
      PV inverter connection, grid switch connector, backup 12V/5Ah battery
      Grid connectionPower switch in the main grid, backup grid and V2G charger by AC contactor
  • Protocol standard
    INFY
      OCPP 1.6J/OCPP 2.0, ISO15118/ISO15118-20, CHAdeMO V1.2, EVPOSSA
  • B2G wallbox converter
    INFY
      Battery side: charge/discharge voltage 300~750V, max power 7kW, max current 23A
      AC side: 100 Vac~264 Vac, 45 Hz~65 Hz, max current 32A, grid connection standard: same to V2G
  • Control
    INFY
      Monitor interfaceLAN 10M/100M and LTE wireless modem support
      Charging indication RGB light barGreen-normal, yellow-charging, blue-discharging, red-failure
      HMITempered glass protective 5" TFT touch screen LCD, RFID support
      MeteringBidirectional mid AC energy meter in optional V2H box
      Hot keyOne EPO key, one V2G action key
  • Reliability and safety
    INFY
      ProtectionIP65, IK10 for cabinet and IK08 for LCD
      EMCRED, EN61000-6-3/EN61000-6-1 Class B, IEC61851-21-2
      SafetyTUV CE, EN 61851-1/EN 61851-23/EN 61851-24, IEC62477-1, IEC62909-1, IEC62909-2
  • Grid connection
    INFY
      AS4777.2
  • Mechanical
    INFY
      Dimensions/weight568mm(H)×340mm(W)×190mm(D)/≤40kg (including the charging connector)
  • Charging cable configuration
    INFY
      40A/750V for CCS2, 37A/500V for CHAdeMO, 32A/750V for GBT
  • Optional pedestal
    INFY
      Pedestal with cable retractors