Product Introduction
EXP600K4 is the 600kW High Power Charger Power Cube with max 10 channels DC output interfaces and 2 channel AC input interfaces.These kinds of full liquid cooled power cubes can be used for the split type V2G and normal EV charger power cube, DC source of the inverter and EV charger functional test and burning test, energy storage power converter cube, DC bus source and many kinds of industrial power supply applications, offering extremely high protection and reliability performance. EXP700K4E is the 700kW high power bidirectional ACDC source with optional max 10 channel DC bus interfaces and 2 channel AC bus interfaces
-
Full safety functions, such as input contactor, input switch, output fuse, EPO, SPD, leakage protection, insulation detection, etc.
-
Flexible configuration: 600kW ACDC, 800kW DCDC and 700kW BiDi ACDC
-
2 sets parallelled to achieve MW power
-
Independent TUV CE/cTUVus certification
-
IP65 high protection
-
Micro AC grid power cube, micro DC grid power cube, EV HPC charger power cube, EV V2G charger power cube, BES power cube
-
Max 10 output channels, can be combined into one
-
60dB ultra low noise
-
Universal liquid cooled power cube
Application
-
600kW ACDC Source
-
700kW ACDC Source
Technical Specification
-
EXP600K4 600kW ACDC
-
EXP700K4E 700kW BiDi ACDC
-
AC side
AC input frequency/voltage 45-65Hz/3-phase+(N)+PE / 260Vac-530Vac AC max power 600kW AC interface 2 channel AC grid interface with RCD breakers and contactors, SPD Power factor >0.99 Total harmonic current <5% (rated input) -
DC side
DC voltage range 150V-1000V DC max power 600kW DC max current 2000A Peak/Full load system efficiency >96%/ >95.7% DC channel 1 or 10 channels configuration -
Metering
2 AC energy meters (opt) -
Monitor
CAN interface -
Parallel work
Support two power cubes parallel work with total output parallel to one bus to MW charging capacity -
HMI
RGB LED, E-STOP -
Mechanical
Dimensions: W * H * D mm = 2050 * 2200 * 850 mm ; weight: 1100 kg + 20 * 30 kg = 1700 kg (full power module and full liquid) -
Protection class
IP65 (excluding heat dissipation compartment) -
Power module
Max 20 * LRG1K0100G 30kW ACDC module -
Power switch
Intelligent power switch among the power module groups, can switch to each output channel to maximize the power efficiency -
Noise
<60dB (rated input and output), max noise <65dB -
Standard
EMC/safety UL2202, CE, EN 61851-21-2/EN 61000-6-4/ EN 61000-6-2 Class A; EN 61851-1/EN 61851-23/EN 61851-24 -
Working Environment
Ambient temperature -25 ~ +70°C, full power output below 50°C, power derating 5%/°C above 50°C Storage temperature -40 ~ +70°C Working humidity 0 ~ 95% Working altitude 2000m
-
AC side
AC input frequency/voltage 45-65Hz/3-phase+(N)+PE / 260Vac-530Vac AC max power 700kW AC interface 2 channel AC grid interface with RCD breakers and contactors, SPD Power factor >0.99 Total harmonic current <5% (rated input) -
DC side
DC voltage range 150V-1000V DC max power 700kW DC max current 2333A Peak/Full load system efficiency >97%/ >96% DC channel 1 or 10 channels configuration -
Metering
2 AC energy meters (opt) -
Monitor
CAN interface -
Parallel work
Support two power cubes parallel work with total output parallel to one bus to MW charging capacity -
HMI
RGB LED, E-STOP -
Mechanical
Dimensions: W * H * D mm = 2050 * 2200 * 850 mm ; weight: 1100 kg + 20 * 30 kg = 1700 kg (full power module and full liquid) -
Protection class
IP65 (excluding heat dissipation compartment) -
Power module
Max 20 * LBG1K0120G 35kW BiDi ACDC module -
Power switch
Intelligent power switch among the power module groups, can switch to each output channel to maximize the power efficiency -
Noise
<60dB (rated input and output), max noise <65dB -
Standard
EMC/safety UL2202, CE, EN 61851-21-2/EN 61000-6-4/ EN 61000-6-2 Class A; EN 61851-1/EN 61851-23/EN 61851-24 -
Working Environment