Product Introduction
EXP600K3 is the 600kW high power charger power cube with max 12 channel DC output interfaces and 2 channel AC input interfaces. This kind of power cube can be used for the DC source of the inverter and EV charger functional test and burning test, split type V2G and normal EV charger power cube, DC bus source and many kinds of industrial power supply applications. EXP440K3E is the 440kW high power bidirectional ACDC source with optional max 12 channel DC bus interfaces and 2 channel AC bus interfaces.
-
Flexible configuration: 600kW/800kW ACDC, 600kW DCDC, 600kW BiDi ACDC, 800kW BiDi DCDC and 500kW low voltage ACDC
-
Full safety functions, such as input contactor, input switch, output fuse, EPO, SPD, leakage protection, insulation detection, etc.
-
Patented U-shaped air duct design
-
Independent TUV CE/cTUVus certification
-
Micro AC grid power cube, micro DC grid power cube, EV HPC charger power cube, EV V2G charger power cube, BES power cube
-
Max 12 output channels, can be combined into one
-
Max 2 sets parallelled to achieve MW power
-
Universal air cooled power cube
-
Lower than 65dB noise
Application
-
600kW ACDC Source
-
440kW BiDi ACDC Source
Technical Specification
-
EXP600K3
-
EXP440K3E
-
AC side
AC input frequency/voltage 45-65Hz/3-phase+(N)+PE/260Vac-530Vac AC max power 600kW AC interface Two channel AC grid interface with RCD breakers and contactors, SPD Power factor >0.99 Total harmonic current <5% (rated input ) -
DC side
DC voltage range 150V-1000V DC max power 600kW DC max current 2000A Peak/full load system efficiency >95.5%/ >95% DC channel 1 to 12 channels configuration -
Metering
2 AC energy meters (opt) -
Monitor
CAN interface -
Parallel work
Support two power cubes parallel work with total output parallel to one bus to MW charging capacity -
HMI
RGB LED, E-STOP -
Mechanical
Dimensions: W * H * D mm = 1050 * 2200 * 1150 mm; weight: 720 kg + 20 * 15.5 kg = 1030 kg (full power modules) -
Protection class
IP54/IK10 -
Power module slot
20 slots -
Power module type
30kW REG1K0100G2 -
Power switch
Intelligent power switch among the power module groups, can switch to each output channel to maximize the power efficiency -
Noise
<65dB (rated input and output) -
Standard
EMC/safety UL2202, CE, EN61851-21-2/EN 61000-6-4/EN 61000-6-2 Class A; EN 61851-1/EN 61851-23/EN 61851-24 -
Working Environment
Ambient temperature Working temperature range -30~+70°C, full load temperature range -25~+50°C, power derating 5%/°C above 50°C Storage temperature -40 ~ +75°C Working humidity 0 ~ 95% Working altitude 2000m
-
AC side
AC input frequency/voltage 45-65Hz/3-phase+(N)+PE/260Vac-530Vac AC max power 440kW AC interface Two channel AC grid interface with RCD breakers and contactors, SPD Power factor >0.99 Total harmonic current <5% (rated input ) -
DC side
DC voltage range 150V-1000V DC max power 440kW DC max current 1466A Peak/full load system efficiency >96.5%/ >96% DC channel 1 to 12 channels configuration -
Metering
2 AC energy meters (opt) -
Monitor
CAN interface -
Parallel work
Support two power cubes parallel work with total output parallel to one bus to MW charging capacity -
HMI
RGB LED, E-STOP -
Mechanical
Dimensions: W * H * D mm = 1050 * 2200 * 1150 mm; weight: 720 kg + 20 * 15.5 kg = 1030 kg (full power modules) -
Protection class
IP54/IK10 -
Power module slot
20 slots -
Power module type
22kW Bidi BEG1K075G -
Power switch
Intelligent power switch among the power module groups, can switch to each output channel to maximize the power efficiency -
Noise
<65dB (rated input and output) -
Standard
EMC/safety UL2202, CE, EN61851-21-2/EN 61000-6-4/EN 61000-6-2 Class A; EN 61851-1/EN 61851-23/EN 61851-24 -
Working Environment
Ambient temperature Working temperature range -30~+70°C, full load temperature range -25~+50°C, power derating 5%/°C above 50°C Storage temperature -40 ~ +75°C Working humidity 0 ~ 95% Working altitude 2000m