INFY INFY
LBG1K0120G

35kW 1000V Liquid Cooled Bidirectional ACDC Power Module

LBG1K0120G.png
INFY

Product Introduction

LBG1K0120G is the bidirectional ACDC power module used to connect the battery or DC bus to the AC grid. It specifically aims for bidirectional applications in V2G/VPF function EV chargers, retired battery utilization and the micro grid. It can also replace traditional PCS for energy storage systems. With the high frequency MOSFET/SiC switch technology, it can achieve excellent performance, high power density, high expansion ability and high reliability. By employing liquid-cooled design, it features high protection and zero noise.

Application

  • V2G application
    INFY
    V2G application.svg
  • BES application
    INFY
    BES application.svg
  • E-LOAD application
    INFY
    E-LOAD application.svg

Product Values

Technical Specification

  • LBG1K0120G
  • Environmental
    INFY
      Ambient temperature/storage temperature-40°C~+75°C/-40°C~+75°C
      Humidity/altitude≤95%RH/2000m
  • AC to DC mode-AC input
    INFY
      Input voltage & current range400/480Vac, 3L+PE; max 68A@320Vac
      Input voltage/frequency range260Vac~530Vac, 45Hz~65Hz
      Power factor≥0.99 ≥ Half-load output power @ rated AC input
      THD≤5% ≥ Half-load output power @ rated AC input
  • AC to DC mode-DC output
    INFY
      Rated power35kW
      Voltage and current range150Vdc~1000Vdc, 0~117A
      Peak efficiency≥97%
      Full load efficiency≥96%
  • AC2DC and DC2AC mode conversion time (with battery test)
    INFY
      10ms
  • DC to AC mode-DC input
    INFY
      DC input voltage rangeOn grid: 150 to 1000Vdc, off grid: 200 to 1000Vdc
      Max input current133A
  • DC to AC mode-AC output
    INFY
      Rated   power35kVA/35kW, 3L+(N)+PE, 50Hz/60Hz
      Output current harmonic content<5%
      Unbalance of three-phase  current2% @steady state, 4%@transient state
      Output power factorUser setting scale, 0.8~1, -0.8~-1
      Low voltage ride through support, anti-islanding support
      Peak efficiency≥97%
      Full load efficiency≥96%
      Off grid-Voltage setting380Vac/400Vac/480Vac (must without N wire at 480Vac)
      Off grid-Power35kVA/31.5kW
      Off grid-Output voltage harmonic content<2% @ full R load/<5% @ full RCD load
      Off grid-Dynamic voltage stability5% @ 20%~100%~20% R load
  • Control
    INFY
      CommunicationCAN bus
      Indication lightGreen LED: ON for AC2DC mode, breathing for DC2AC mode; yellow LED: alarm; red LED: failure
  • Power module in parallel
    INFY
      Max number: on grid: 32, off grid: 15
  • Cooling requirement
    INFY
      Coolant typeG65 antifreeze (60% Ethylene Glycol + 40% pure H2O)
      Coolant temperature range-20°C~+60°C with full load, power derating above 60°C
      Coolant flow requirement6L~10L/min, min 0.22 bar pressure difference between the input and output liquid interface
      Coolant pressure/volumeMax 120PSI 8 bar, 0.25L in the module
  • Protection
    INFY
      IP30 with condensation water protection design
  • EMC
    INFY
      TUV CE certificationEN61000-6-1/-2/-3/-4 Class B
  • Safety
    INFY
      cTUVus/TUV CE certificationUL2202, CSA C22.2 No. 107.1, UL9741, UL1741, IEC62909, EN62477
  • Grid connection
    INFY
      Multi-country grid conformityVDE-AR-N 4105, EN50549-1: 2019, EN50549-10: 2022, UL 1741SB: 2021, IEEE 1547: 2018, IEEE 1547.1: 2020
  • Mechanical
    INFY
      Dimensions/weight: 123mm (H) × 300mm (W) × 453mm (D) (excluding the holder and interface plug), ≤ 32kg